da12b98 Issue 50655 - etime displayed has an order of magnitude 10 times smaller than it should be

Authored and Committed by sgouvern 4 years ago
    Issue 50655 - etime displayed has an order of magnitude 10 times smaller than it should be
    
    Description:
    	Time value in nanoseconds displayed in the access log was 10 times lower than the actual value.
    	This test is intented to verify the fix for this problem.
    
    Relates https://bugzilla.redhat.com/show_bug.cgi?id=1749236
    
    Author: sgouvern
    
    Review by: firstyear, spichugi