#2072 xen11 disk problems
Closed: Fixed None Opened 14 years ago by smooge.

= phenomenon =

= reason =

= recommendation =

xen11 (an HPUX amd64 system) is experiencing disk problems. Need to work with HP-UX and get new disks.


Ran the following commands on system to see status

719 hpacucli controller serialnumber=P61630H9SVU4JF array A show
720 hpacucli controller serialnumber=P61630H9SVU4JF array B show
721 hpacucli controller serialnumber=P61630H9SVU4JF array C show
722 hpacucli controller serialnumber=P61630H9SVU4JF array D show
723 hpacucli controller serialnumber=P61630H9SVU4JF array E show
724 hpacucli controller serialnumber=P61630H9SVU4JF array F show
725 hpacucli controller serialnumber=P61630H9SVU4JF array G show
726 hpacucli controller serialnumber=P61630H9SVU4JF array H show

Removed disk

824 mdadm /dev/md0 --remove /dev/cciss/c0d1p1
825 mdadm /dev/md1 --remove /dev/cciss/c0d1p2
826 mdadm /dev/md1 --remove /dev/cciss/c0d1p3
827 mdadm /dev/md2 --remove /dev/cciss/c0d1p3
828 mdadm /dev/md3 --remove /dev/cciss/c0d1p4

hpacucli controller serialnumber=P61630H9SVU4JF show config
array B (SATA, Unused Space: 0 MB)

  logicaldrive 2 (698.6 GB, RAID 0, Failed)

  physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK)

hpacucli controller serialnumber=P61630H9SVU4JF logicaldrive 2 delete

Warning: Deleting an array can cause other array letters to become renamed.
E.g. Deleting array A from arrays A,B,C will result in two remaining
arrays A,B ... not B,C

Warning: Deleting the specified device(s) will result in data being lost.
Continue? (y/n) y

hpacucli controller serialnumber=P61630H9SVU4JF create type=ld drives=1I:1:1 raid=0

s/HP-UX/HP/

having enough problems with this system to not add in HPUX onto it.

Service technician dispatched Case # 461 255 4580

Drive replaced. 72 hours of running and no problems.